Reverse Osmosis

ShriRam Oxyair

For ShriRam Oxyair in Bhavnagar, Aim Enviro designed, installed, and commissioned a 25,000 LPH two-stage rooftop Reverse Osmosis plant engineered for high water recovery.

Client

ShriRam Oxyair

Location

Bhavnagar, Gujarat

Capacity

25,000 LPH

Category

Reverse Osmosis

Overview

25,000 LPH Two-Stage RO Plant

ShriRam Oxyair needed a rooftop-installed RO system capable of reliably supplying process water at scale. Aim Enviro engineered a 25,000 LPH two-stage Reverse Osmosis plant: Stage 1 uses 3 pressure tubes for primary separation, with the concentrate routed into a Stage 2 array of 2 pressure tubes for additional permeate recovery.

The two-stage pressure tube design achieves approximately 75% water recovery, and the system was successfully installed, commissioned, and handed over on the client's rooftop facility.

ShriRam Oxyair rooftop RO plant handover

Scope of Work

What We Delivered

  • Water quality assessment and RO system design for 25,000 LPH capacity
  • Design of a two-stage pressure tube configuration (3 PT + 2 PT)
  • Rooftop installation and commissioning of the RO plant
  • Performance testing and handover to ShriRam Oxyair

Technologies Used

Two-Stage RO

At a Glance

Project Specifications

Client

ShriRam Oxyair

Location

Bhavnagar, Gujarat

Capacity

25,000 LPH

Recovery Rate

~75%

Configuration

Stage 1: 3 Pressure Tubes → Stage 2: 2 Pressure Tubes

Core Goals

  • Deliver 25,000 LPH of process water via a rooftop-installed RO plant
  • Achieve approximately 75% water recovery within a space-constrained rooftop layout
  • Commission and hand over a fully operational system to the client

Key Challenges

  • Designing a compact two-stage RO layout suited to rooftop installation
  • Balancing feed pressure across the 3 PT (Stage 1) and 2 PT (Stage 2) arrays
  • Coordinating rooftop logistics for equipment installation and commissioning

Process

System Configuration

01

Feed Water

02

RO Stage 1 — 3 Pressure Tubes

03

RO Stage 2 — 2 Pressure Tubes

04

Permeate (~75% Recovery)

Highlights

  • Pressure tube configuration (3 PT + 2 PT) engineered specifically for ~75% recovery
  • Compact two-stage layout designed for rooftop installation constraints
  • Installation and commissioning coordinated for rooftop site logistics

How We Work

Our Project Execution Methodology

01

Requirement Analysis

Understanding water quality, capacity, and application requirements for the project.

02

Water Testing & Site Study

Sampling and analyzing raw water or effluent, and assessing site conditions and constraints.

03

Design & Engineering

Detailed process design, equipment sizing, and engineering drawings tailored to the project.

04

Equipment Selection

Sourcing and specifying equipment matched to capacity, technology, and site requirements.

05

Installation & Commissioning

Mechanical and electrical installation, system integration, and trial runs.

06

Performance Testing

Validating output quality and system performance against design targets.

07

AMC & O&M Support

Ongoing maintenance, monitoring, and operational support after handover.

Key Benefits

Results That Matter

25,000 LPH capacity engineered for rooftop installation
Approximately 75% water recovery from available feed water
Two-stage configuration maximizes permeate yield
Successfully commissioned and handed over to the client

Gallery

Project Gallery

0:000:00

Collaboration

Project Partners

Delivered through close collaboration between Aim Enviro's engineering team and the client.

ShriRam Oxyair
Aim Enviro Private Limited

Need a Rooftop RO Installation?

Talk to Aim Enviro about designing a space-efficient, high-recovery RO plant for your facility.